{"id":5086,"date":"2022-03-28T08:56:34","date_gmt":"2022-03-28T00:56:34","guid":{"rendered":"https:\/\/www.hnyt99.com\/?p=5086"},"modified":"2022-03-28T08:59:39","modified_gmt":"2022-03-28T00:59:39","slug":"230","status":"publish","type":"post","link":"https:\/\/www.hnyt99.com\/baike\/hybz\/230.html","title":{"rendered":"\u4f9b\u6c34\u6392\u6c34\u884c\u4e1a\u5e38\u7528\u672f\u8bed\uff08\u4e2d\u82f1\u6587\uff09"},"content":{"rendered":"\n
1\u3001 \u6700\u5927\u65f6\u7528\u6c34\u91cf maximum hourly water consumption<\/p>\n\n\n\n
\u6700\u9ad8\u65e5\u6700\u5927\u7528\u6c34\u65f6\u6bb5\u5185\u7684\u5c0f\u65f6\u7528\u6c34\u91cf\u3002<\/p>\n\n\n\n
2\u3001\u5e73\u5747\u65f6\u7528\u6c34\u91cf average hourly water consumption<\/p>\n\n\n\n
\u6700\u9ad8\u65e5\u7528\u6c34\u65f6\u6bb5\u5185\u7684\u5e73\u5747\u5c0f\u65f6\u7528\u6c34\u91cf\u3002<\/p>\n\n\n\n
3\u3001\u5012\u6d41\u9632\u6b62\u5668 backflow prevent<\/p>\n\n\n\n
\u4e00\u79cd\u91c7\u7528\u6b62\u56de\u90e8\u4ef6\u7ec4\u6210\u7684\u53ef\u9632\u6b62\u7ed9\u6c34\u7ba1\u9053\u6c34\u6d41\u5012\u6d41\u7684\u88c5\u7f6e\u3002<\/p>\n\n\n\n
4\u3001\u771f\u7a7a\u7834\u574f\u5668 vacuum breakers<\/p>\n\n\n\n
\u4e00\u79cd\u53ef\u5bfc\u5165\u5927\u6c14\u538b\u6d88\u9664\u7ed9\u6c34\u7ba1\u9053\u5185\u6c34\u6d41\u56e0\u8679\u5438\u800c\u5012\u6d41\u7684\u88c5\u7f6e<\/p>\n\n\n\n
5\u3001 \u53e0\u538b\u4f9b\u6c34 additive pressure water supply<\/p>\n\n\n\n
\u5229\u7528\u5ba4\u5916\u7ed9\u6c34\u7ba1\u7f51\u4f59\u538b\u76f4\u63a5\u62bd\u6c34\u518d\u589e\u538b\u7684\u4e8c\u6b21\u4f9b\u6c34\u65b9\u5f0f\u3002<\/p>\n\n\n\n
6\u3001\u81ea\u704cself-priming<\/p>\n\n\n\n
\u6c34\u6cf5\u542f\u52a8\u65f6\u6c34\u9760\u91cd\u529b\u5145\u5165\u6cf5\u4f53\u7684\u5f15\u6c34\u65b9\u5f0f\u3002<\/p>\n\n\n\n
7\u3001\u81ea\u5faa\u73af\u901a\u6c14 auto circulation venting<\/p>\n\n\n\n
\u901a\u6c14\u7acb\u7ba1\u5728\u9876\u7aef\u3001\u5c42\u95f4\u548c\u6392\u6c34\u7acb\u7ba1\u76f8\u8fde\uff0c\u5728\u5e95\u7aef\u4e0e\u6392\u51fa\u7ba1\u8fde\u63a5\uff0c\u6392\u6c34\u65f6\u5728\u7ba1\u9053\u5185\u4ea7\u751f\u7684\u6b63\u8d1f\u538b\u901a\u8fc7\u8fde\u63a5\u7684\u901a\u6c14\u7ba1\u9053\u8fc2\u56de\u8865\u6c14\u800c\u8fbe\u5230\u5e73\u8861\u7684\u901a\u6c14\u65b9\u5f0f\u3002<\/p>\n\n\n\n
8\u3001\u771f\u7a7a\u6392\u6c34 vacuum drain<\/p>\n\n\n\n
\u5229\u7528\u771f\u7a7a\u8bbe\u5907\u4f7f\u6392\u6c34\u7ba1\u9053\u5185\u4ea7\u751f\u4e00\u5b9a\u771f\u7a7a\u5ea6\uff0c\u5229\u7528\u7a7a\u6c14\u8f93\u9001\u4ecb\u8d28\u7684\u6392\u6c34\u65b9\u5f0f\u3002<\/p>\n\n\n\n
9\u3001 \u540c\u5c42\u6392\u6c34 same-floor drainage<\/p>\n\n\n\n
\u6392\u6c34\u6a2a\u652f\u7ba1\u5e03\u7f6e\u5728\u6392\u6c34\u5c42\u6216\u5ba4\u5916\uff0c\u5668\u5177\u6392\u6c34\u7ba1\u4e0d\u7a7f\u697c\u5c42\u7684\u6392\u6c34\u65b9\u5f0f\u3002<\/p>\n\n\n\n
10\u3001\u57cb\u8bbe\u6df1\u5ea6 buried depth<\/p>\n\n\n\n
\u57cb\u5730\u6392\u6c34\u7ba1\u9053\u5185\u5e95\u81f3\u5730\u8868\u9762\u7684\u5782\u76f4\u8ddd\u79bb\u3002<\/p>\n\n\n\n
11\u3001\u9694\u6cb9\u5668grease interceptor<\/p>\n\n\n\n
\u5206\u9694\u3001\u62e6\u96c6\u751f\u6d3b\u5e9f\u6c34\u4e2d\u6cb9\u8102\u7684\u88c5\u7f6e\u3002<\/p>\n\n\n\n
12\u3001\u4e2d\u6c34 reclaimed water<\/p>\n\n\n\n
\u5404\u79cd\u6392\u6c34\u7ecf\u9002\u5f53\u5904\u7406\u8fbe\u5230\u89c4\u5b9a\u7684\u6c34\u8d28\u6807\u51c6\u540e\u56de\u7528\u7684\u6c34\u3002<\/p>\n\n\n\n
13\u3001\u66b4\u96e8\u5f3a\u5ea6 rainfall intensity<\/p>\n\n\n\n
\u5355\u4f4d\u65f6\u95f4\u5185\u7684\u964d\u96e8\u91cf\u3002<\/p>\n\n\n\n
14\u3001\u964d\u96e8\u5386\u65f6 duration of rainfall<\/p>\n\n\n\n
\u964d\u96e8\u8fc7\u7a0b\u4e2d\u7684\u4efb\u610f\u8fde\u7eed\u65f6\u6bb5\u3002<\/p>\n\n\n\n
15\u3001\u5730\u9762\u96c6\u6c34\u65f6\u95f4 inlet time<\/p>\n\n\n\n
\u96e8\u6c34\u4ece\u76f8\u5e94\u6c47\u6c34\u9762\u79ef\u7684\u6700\u8fdc\u70b9\u5730\u8868\u5f84\u6d41\u5230\u96e8\u6c34\u7ba1\u6e20\u5165\u53e3\u7684\u65f6\u95f4\u3002\u7b80\u79f0\u96c6\u6c34\u65f6\u95f4\u3002<\/p>\n\n\n\n
16\u3001\u7ba1\u5185\u6d41\u884c\u65f6\u95f4 time of flow<\/p>\n\n\n\n
\u96e8\u6c34\u5728\u7ba1\u6e20\u4e2d\u6d41\u884c\u7684\u65f6\u95f4\u3002\u7b80\u79f0\u6d41\u884c\u65f6\u95f4\u3002<\/p>\n\n\n\n
17\u3001\u6c47\u6c34\u9762\u79ef catchment area<\/p>\n\n\n\n
\u96e8\u6c34\u7ba1\u6e20\u6c47\u96c6\u964d\u96e8\u7684\u9762\u79ef\u3002<\/p>\n\n\n\n
18\u3001\u6ee1\u7ba1\u538b\u529b\u6d41\u96e8\u6c34\u6392\u6c34\u7cfb\u7edf full pressure storm system<\/p>\n\n\n\n
\u6309\u6ee1\u7ba1\u538b\u529b\u6d41\u539f\u7406\u8bbe\u8ba1\u7ba1\u9053\u5185\u96e8\u6c34\u6d41\u91cf\u3001\u538b\u529b\u7b49\u53ef\u5f97\u5230\u6709\u6548\u63a7\u5236\u548c\u5e73\u8861\u7684\u5c4b\u9762\u96e8\u6c34\u6392\u6c34\u7cfb\u7edf\u3002<\/p>\n\n\n\n
19\u3001\u5f84\u6d41\u7cfb\u6570 run-off coefficient<\/p>\n\n\n\n
\u4e00\u5b9a\u6c47\u6c34\u9762\u79ef\u7684\u5f84\u6d41\u96e8\u6c34\u91cf\u4e0e\u964d\u96e8\u91cf\u7684\u6bd4\u503c\u3002<\/p>\n\n\n\n
20\u3001\u96c6\u4e2d\u70ed\u6c34\u4f9b\u5e94\u7cfb\u7edf central hot water supply system<\/p>\n\n\n\n
\u4f9b\u7ed9\u4e00\u5e62(\u4e0d\u542b\u5355\u5e62\u522b\u5885)\u6216\u6570\u5e62\u5efa\u7b51\u7269\u6240\u9700\u70ed\u6c34\u7684\u7cfb\u7edf\u3002<\/p>\n\n\n\n
21\u3001\u5c40\u90e8\u70ed\u6c34\u4f9b\u5e94\u7cfb\u7edf local hot water supply system<\/p>\n\n\n\n
\u4f9b\u7ed9\u5355\u4e2a\u6216\u6570\u4e2a\u914d\u6c34\u70b9\u6240\u9700\u70ed\u6c34\u7684\u4f9b\u5e94\u7cfb\u7edf\u3002<\/p>\n\n\n\n
22\u3001\u5168\u65e5\u70ed\u6c34\u4f9b\u5e94\u7cfb\u7edfall day hot water supply system<\/p>\n\n\n\n
\u5728\u5168\u65e5\u3001\u5de5\u4f5c\u73ed\u6216\u8425\u4e1a\u65f6\u95f4\u5185\u4e0d\u95f4\u65ad\u4f9b\u5e94\u70ed\u6c34\u7684\u7cfb\u7edf\u3002<\/p>\n\n\n\n
23\u3001\u5b9a\u65f6\u70ed\u6c34\u4f9b\u5e94\u7cfb\u7edf fixed time hot water supply system<\/p>\n\n\n\n
\u5728\u5168\u65e5\u3001\u5de5\u4f5c\u73ed\u6216\u8425\u4e1a\u65f6\u95f4\u5185\u67d0\u4e00\u65f6\u6bb5\u4f9b\u5e94\u70ed\u6c34\u7684\u7cfb\u7edf\u3002<\/p>\n\n\n\n
24\u3001 \u70ed\u6cf5\u70ed\u6c34\u4f9b\u5e94\u7cfb\u7edf heat pump hot water system<\/p>\n\n\n\n
\u901a\u8fc7\u70ed\u6cf5\u673a\u7ec4\u8fd0\u884c\u5438\u6536\u73af\u5883\u4f4e\u6e29\u70ed\u80fd\u5236\u5907\u548c\u4f9b\u5e94\u70ed\u6c34\u7684\u7cfb\u7edf\u3002<\/p>\n\n\n\n
25\u3001\u6c34\u6e90\u70ed\u6cf5 heat pump of water source<\/p>\n\n\n\n
\u4ee5\u6c34\u6216\u6dfb\u52a0\u9632\u51bb\u5242\u7684\u6c34\u6eb6\u6db2\u4e3a\u4f4e\u6e29\u70ed\u6e90\u7684\u70ed\u6cf5\u3002<\/p>\n\n\n\n
26\u3001 \u7a7a\u6c14\u6e90\u70ed\u6cf5 heat pump of air source<\/p>\n\n\n\n
\u4ee5\u73af\u5883\u7a7a\u6c14\u4e3a\u4f4e\u6e29\u70ed\u6e90\u7684\u70ed\u6cf5\u3002<\/p>\n\n\n\n
27\u3001 \u592a\u9633\u80fd\u4fdd\u8bc1\u7387 solar fraction<\/p>\n\n\n\n
\u7cfb\u7edf\u4e2d\u7531\u592a\u9633\u80fd\u90e8\u5206\u63d0\u4f9b\u7684\u70ed\u91cf\u9664\u4ee5\u7cfb\u7edf\u603b\u8d1f\u8377\u3002<\/p>\n\n\n\n
28\u3001\u592a\u9633\u5e45\u7167\u91cf solar irradiation<\/p>\n\n\n\n
\u63a5\u6536\u5230\u592a\u9633\u8f90\u5c04\u80fd\u7684\u9762\u5bc6\u5ea6\u3002<\/p>\n\n\n\n
29\u3001\u71c3\u6cb9(\u6c14)\u70ed\u6c34\u673a\u7ec4 butning oil and gas hot water heaters<\/p>\n\n\n\n
\u7531\u71c3\u70e7\u5668\u3001\u6c34\u52a0\u70ed\u7089\u4f53(\u7089\u4f53\u6c34\u5957\u4e0e\u5927\u6c14\u76f8\u901a\uff0c\u5448\u5e38\u538b\u72b6\u6001)\u548c\u71c3\u6cb9(\u6c14)\u4f9b\u5e94\u7cfb\u7edf\u7b49\u7ec4\u6210\u7684\u8bbe\u5907\u7ec4\u5408\u4f53\u3002<\/p>\n\n\n\n
30\u3001\u8bbe\u8ba1\u5c0f\u65f6\u8017\u70ed\u91cf design heat consumption of maximum time<\/p>\n\n\n\n
\u70ed\u6c34\u4f9b\u5e94\u7cfb\u7edf\u4e2d\u7528\u6c34\u8bbe\u5907\u3001\u5668\u5177\u6700\u5927\u65f6\u6bb5\u5185\u7684\u8017\u70ed\u91cf\u3002<\/p>\n\n\n\n
31\u3001\u8bbe\u8ba1\u5c0f\u65f6\u4f9b\u70ed\u91cf design heat supply of maximum time<\/p>\n\n\n\n
\u70ed\u6c34\u4f9b\u5e94\u7cfb\u7edf\u4e2d\u52a0\u70ed\u8bbe\u5907\u6700\u5927\u65f6\u6bb5\u5185\u7684\u4ea7\u70ed\u91cf\u3002<\/p>\n\n\n\n
32\u3001\u540c\u7a0b\u70ed\u6c34\u4f9b\u5e94\u7cfb\u7edf reversed return hot water system<\/p>\n\n\n\n
\u5bf9\u5e94\u6bcf\u4e2a\u914d\u6c34\u70b9\u7684\u4f9b\u6c34\u4e0e\u56de\u6c34\u7ba1\u8def\u957f\u5ea6\u4e4b\u548c\u57fa\u672c\u76f8\u7b49\u7684\u70ed\u6c34\u4f9b\u5e94\u7cfb\u7edf\u3002<\/p>\n\n\n\n
33\u3001\u7b2c\u4e8c\u5faa\u73af\u7cfb\u7edf hot water circulation system<\/p>\n\n\n\n
\u96c6\u4e2d\u70ed\u6c34\u4f9b\u5e94\u7cfb\u7edf\u4e2d\uff0c\u6c34\u52a0\u70ed\u5668\u6216\u70ed\u6c34\u8d2e\u6c34\u5668\u4e0e\u70ed\u6c34\u914d\u6c34\u70b9\u4e4b\u95f4\u7ec4\u6210\u7684\u70ed\u6c34\u5faa\u73af\u7cfb\u7edf\u3002<\/p>\n\n\n\n
34\u3001\u7ba1\u9053\u76f4\u996e\u6c34\u7cfb\u7edf purified drinking water system<\/p>\n\n\n\n
\u539f\u6c34\u7ecf\u6df1\u5ea6\u51c0\u5316\u5904\u7406\uff0c\u901a\u8fc7\u7ba1\u9053\u8f93\u9001\uff0c\u4f9b\u4eba\u4eec\u76f4\u63a5\u996e\u7528\u7684\u4f9b\u6c34\u7cfb\u7edf\u3002<\/p>\n\n\n\n
35\u3001\u6c34\u8d28\u963b\u57a2\u7f13\u8680\u5904\u7406 water quality treatment of scale-prevent & corrosion-delay<\/p>\n\n\n\n
\u91c7\u7528\u7535\u3001\u78c1\u3001\u5316\u5b66\u7a33\u5b9a\u5242\u7b49\u7269\u7406\u3001\u5316\u5b66\u65b9\u6cd5\u7a33\u5b9a\u6c34\u4e2d\u9499\u3001\u9541\u79bb\u5b50\uff0c\u4f7f\u5176\u5728\u4e00\u5b9a\u7684\u6761\u4ef6\u4e0b\u4e0d\u5f62\u6210\u6c34\u57a2\uff0c\u5ef6\u7f13\u5bf9\u52a0\u70ed\u8bbe\u5907\u6216\u7ba1\u9053\u7684\u8150\u8680\u7684\u6c34\u8d28\u5904\u7406\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"